SafeOne Personal RF Monitor for FCC, OSHA Safety Compliance in RF and Tower Workplaces

 

 

 

 

 

 



 

 

 

 

             Technical Data 
Frequency range:              10 –10000 MHz
Frequency profile:     
           ICNIRP - IEEE
Abs. accuracy:         400- 2500 MHz ± 6 dB
Indicated power:             0.1 – 10 mW/cm2
Field strength:                      19 – 137 V/m
Dynamic range:                              > 30 dB
Audio alarm intensity:
                    80 dBa
Timed sleep mode:
                     5 minutes
Power supply:
                     3 Volt (2 x AAA)
Battery life, w/o audio alarm:     +500  days
EMI/RFI:
                          EN55022/B
Dimensions:
         inch 
2.3 x 4.2 x 0.9
W x H x D                       mm 58 x 105 x 23
Weight with batteries::       3oz   (88 grams)
Oper. temperature:
         10  to 104 °F 
                                          -10 to +40 °C 
Color:           
                        Black & Grey
LBA Model#                                   SI 1000

     
 LBA RF Awareness
Training Here

Latest RF Safety RFQ's

 

SafeOne™
Personal RF Safety Monitor                

SafeOne Personal RF Monitor•Alerts to Hazardous RF Exposures

•Meets FCC, OSHA, and WHO Guidlines

•Visual and Audio Alarms

•Wide Radio Frequency Range

•Rugged, Professional Construction

•Best Value Pricing
  Order Now  

Limited Time Special Introductory Price!
FREE Shipping*

 

SafeOne™ personal RF safety monitors are an effective and economical means to monitor the strength of electromagnetic (RF) fields from mobile phone towers, microwave ovens, radio and television installations, high frequency welders, and other common workplace RF sources between 10 and 10,000 MHz. The Personal RF Monitor is essential RF safety equipment in complying with FCC, OSHA, and other safe workplace requirements.

SafeOne™ personal RF safety monitors give you audio and visual warning when the IEEE and ICNIRP limit is exceeded on your body. It immediately alerts you to high frequency radia­tion fields that could be a health hazard. SafeOne™ gives an approximate value of RF strength to help you determine how long you can stay in the radiation field.

Extremely convenient to wear and use, the SafeOne™  personal RF safety monitor is the size of a cell phone and weighs under 3 ounces! It's smaller and much lighter than competing units!

Using Your SafeOne™

Wearing Your Monitor
The SafeOne™ personal RF monitor should be worn on the belt with the supplied belt clip, or clipped to a harness in the optional carry pouch. Position the Personal Monitor clear of metallic objects, such as a tool pouch. The SafeOne™ personal RF monitor should not be used with an RF protective suit.

Preparation for Use
To start using SafeOne™ personal RF protection, simply unscrew the battery cover on the back and insert two AAA alkaline batteries, perform a functional test, and set desired alarm parameters.

No need to worry about the batteries - the SafeOne™ pocket RF monitor's batteries can last over 500 days!

The monitor incorporates a self-test function to be used whenever the monitor is turned on.

Interpreting Your Monitor
The SafeOne™ personal RF monitor uses a simple set of audible and visual alarms to alert you to dangerous radio frequency (RF) fields. Those alarms can be set for your convenience.

When SafeOne™ RF radiation monitors give an alarm, it means that your RF exposure may be above FCC, OSHA, or ICNIRP limits. When this occurs, you should leave the area and proceed in accordance with your company’s RF safety plan or consult the appropriate workplace authority.

Setting Alarm / Function Features
SafeOne™
has 2 alarm levels and 3 alarm functions. All functions are controlled by pressing the SELECT pushbutton. When SELECT is pushed there is audio and visual feedback.

The World Health Organization has established health hazard limits that are accepted in most parts of the world as standards. In the United States, these are standards of the FCC and OSHA. The radiofrequency exposure, Maximum Permissable Exposure (MPE) limits are divided into two levels, one for “General Public” use and one for persons trained to work in high frequency radiation areas, referred to as “Occupational”.

Your RF monitor can be set to these two alarm levels. The lower "Public" level is automatically chosen when SafeOne™ personal RF protection is turned on. To choose "Occupational", press and hold the SELECT pushbutton for more than 5 seconds. The unit will respond with 10 long or 10 short beeps. The chosen level is indicated by a lighted bar.

By pushing the SELECT button momentarily, the 3 different RF safety alarm functions can be chosen:

  • Normal (one beep): In this position the SafeOne™ personal RF safety monitor will give both audible and visual warning, when the chosen alarm limit is exceeded.
  • Timer (two beeps): SafeOne™ will only give visual warning, when the chosen alarm limit is exceeded. After approximately 5 minutes SafeOne™ will beep and return to normal position.
  • Silent (three beeps): SafeOne™ will only give visual warning when the chosen RF safety alarm limit is exceeded.

Maintaining Your Monitor
No routine maintenance is needed to keep your SafeOne™ personal RF monitor in good order! Just take common sense measures to keep it clean, dry, and secure.

Calibration services are available.

 

   Order Your SafeOne™ Now
Special Introductory Price


     Only
$675 US*
            (Quantity Discounts Available)

 
Accepted

Order Here

or contact
Jerry Brown
(USA & Worldwide)
Javier Castillo (Latin America)
252-757-0279
or  800-522-4464

*No charge for ground shipment within the continental United States. Expedited shipping and handling will be charged extra. Duties and taxes are extra as required by destination. Offered for professional use only.

Suggested Research Topics on Personal RF Protection:

rf personal monitors, electromagnetic radiation meter, radio frequency safety, rf exposure, rf monitor, nardalert, rf exposure meter, rf field meter, safeone, rf alert, osha tower, rf radiation exposure, rf radiation monitor, nardalert xt, narda radman, rf antenna safety, electromagnetic radiation monitor, rf exposure, narda rf, radio frequency safety, rf burns, radio frequency radiation, rf danger, microwave exposure, heat sealer rf, radio frequency alert, rf osha, rf radiation safety, rf radiation hazard, rf safety equipment, radio frequency hazards, radio frequency exposure, rf exposure limits, fcc rf exposure, radio frequency radiation exposure, exposure to radio frequency, rf exposure safety, exposure to rf, radio frequency osha, human exposure to radio frequency electromagnetic fields, microwave energy exposure, rf safety on towers, tower climber rf safety, rf protection for tower workers, rf exposure guidelines, fcc rf exposure limits, rf safety monitor, belt rf monitor, emf safety monitor, narda radman monitor, osha rf monitors, pocket rf monitor, rf energy exposure, antenna safety, climber safety, microwave safety, rf protection, rf industrial safety, osha safety, osha safety standards, osha safety compliance, osha safety regulations, rf survey, compliance rf, rf hazard assessment, rf protective clothing, equipment rf safety, radio safety international, safety compliance, emf safety, industrial rf protection


Check it out!


LBA Site Search




3400 Tupper Drive (27834), P.O. Box 8026
Greenville, North Carolina 27835
800-522-4464 / 252-757-0279 / Fax 252-752-9155
Email:

Copyright 2007. LBA Group, Inc. All Rights Reserved.